- | In these notes, we will examine a few examples of changing magnetic fluxes and associated induced voltages. | + | In these notes, we will examine a few examples of changing magnetic fluxes and associated induced voltages. |
- | First let's consider when $\Phi_B$ rises and falls linearly with the same magnitude of slope: | + | $$V_{ind} = -\frac{d\Phi_b}{dt}$$ |
+ | |||
+ | This is saying that the induced current is the **negative slope** of the magnetic flux. In other words, if the magnetic flux is increasing, then $V_{ind}$ will be negative, if the magnetic flux is decreasing, then $V_{ind}$ will be positive, and if the magnetic flux is constant, then $V_{ind} = 0$. | ||
+ | |||
+ | First let's consider when an example where $\Phi_B$ rises and falls linearly with the same magnitude of slope: | ||
Line 26: | Line 30: | ||
\end{cases} | \end{cases} | ||
$$ | $$ | ||
- | Which finally means that $V_{ind}$ | + | Now we can multiply by $-1$ because of the negative sign in Faraday' |
$$ | $$ | ||
V_{ind}= | V_{ind}= | ||
Line 39: | Line 43: | ||
[{{184_notes: | [{{184_notes: | ||
- | We can see that from $t=0$ to $t = 10$, $\Phi_B(t)$ has a positive slope, so $V_{ind}$ is negative on that time interval. However, $\Phi_B(t)$ is steeper from $t=5$ to $t=10$, so $V_{ind}$ is **more negative** on that time interval than from $t = 0$ to $t = 5$. From $t = 10$ to $t = 15$, $\Phi_B(t)$ has a constant and negative slope, so $V_{ind}$ is constant and positive on that time interval. | + | We can see that from $t=0$ to $t = 10$, $\Phi_B(t)$ has a positive slope, so $V_{ind}$ is negative on that time interval. However, $\Phi_B(t)$ is steeper from $t=5$ to $t=10$, so $V_{ind}$ is **more negative** on that time interval than from $t = 0$ to $t = 5$. From $t = 10$ to $t = 15$, $\Phi_B(t)$ has a constant and negative slope, so $V_{ind}$ is constant and positive on that time interval. |
+ | |||
+ | |||
+ | $$ | ||
+ | \Phi_B(t)= | ||
+ | \begin{cases} | ||
+ | 2t & \text{if } 0< | ||
+ | 5t -15 & \text{if } 5< | ||
+ | -10t + 135 & \text{if } 10< | ||
+ | \end{cases} | ||
+ | $$ | ||
+ | Which means $\frac{d \Phi_B}{dt}$ is: | ||
+ | $$ | ||
+ | \frac{d \Phi_B}{dt}= | ||
+ | \begin{cases} | ||
+ | 2 & \text{if } 0< | ||
+ | 5 & \text{if } 5< | ||
+ | -10 & \text{if } 10< | ||
+ | \end{cases} | ||
+ | $$ | ||
+ | Which finally means that $V_{ind}$ is: | ||
+ | $$ | ||
+ | V_{ind}= | ||
+ | \begin{cases} | ||
+ | -2 & \text{if } 0< | ||
+ | -5 & \text{if } 5< | ||
+ | 10 & \text{if } 10< | ||
+ | \end{cases} | ||
+ | $$ | ||
Finally, let's look at an example with a non-linear $\Phi_B(t)$: | Finally, let's look at an example with a non-linear $\Phi_B(t)$: |